Liner: PFA
Process Connection:PN16, St37-2/FE 410W B, flange EN1092-1 (DIN2501
Electrodes: 1.4435/316L
Calibration:0.2%
Additional Test, certificate: w/o
Approval:Non-hazardous area
Housing: Compact Alu, IP67 NEMA4X
Cable, Remote Version: Not used
Cable Entry: Gland M20 (EEx d > thread M20)
Adjustment; Software Feature: Factory setup; basic version
Output, Input:4-20mA SIL HART + frequency